Use of Explosives & Safety Measures

 

Use of Explosives & Safety Measures


1.Local Authorities - The use of explosives will be strictly controlled by the local Authorities. They will lay down the conditions/procedures for the transportation and storage of explosives.

2.Ensure all the explosives stores shall be clean and dry. The iron should not be exposed inside the store. It shall be kept securely locked at all times when not actually in use and the lock key shall be kept by a accountable employee nominated by the company management.

3.Any Ignition Source - No smoking or any means of ignition shall be allowed within 50 meters (min.) of any explosives. Any kind of tools used in the explosive material store shall be wood or non-sparking material properties.

4.Removing of explosives from the wrapping - Explosive shall not be removed from its immediate wrapping, or cartridge wrapping within the store. Always ensure the Detonators shall be stored and transported separately from the bulk explosives.

Safety Warning Signs for Workplace Awareness

5.Issue of explosives - All explosives, detonators and related equipment shall only be issued against a proper requisition as per the company procedures which is signed by an authorized supervisor or Manager.

6.Competent Employee - Explosives shall only be handled or used by a competent employee. He shall be properly trained and experienced and shall be appointed in writing by Management Only the competent employee may draw explosives from the store. The competent employee has to be provided for all the required Personal Protective Equipment(PPE) for handling the explosives. He shall sign for the quantity of each item received, and shall be appointed in writing by the company Management.

7.Blasting Work – Ensure the immediate area shall be cleared of all employees/visiting personnel other than those engaged in the blasting work before setting the charges of blasting.

8. Ensure the flagmen shall be posted in prominent locations on the perimeter of the blasting area. Flagman shall prevent the entry of employees to the blasting area and indicate by signal to the competent blasting employee that the area is clear before he fire the blasting charge.

Height Work Working At Height Basic






Heat Stress

 

Heat Stress

Heat Stress

The exposure to heat can cause illness and severe health concerns to employees especially those who working in outdoor jobs. The most serious heat illness is heat stroke. Other heat illnesses, such as heat exhaustion, heat cramps and heat rash, should also be avoided, the following measures and precautions to be considered.

1.Understand that heat stress is a normal physical condition which is caused by any physical exertion. However, when employees directly exposed to sunrays, temperatures can exceed 50 ºC (120 ºF), which may lead to other adverse health effects because of this exposure.

2. Drinking enough water - Heat exhaustion can occur if an employee becomes too hot, expends too much energy, and does not drink enough required water for the body. Heat exhaustion is generally not dangerous and the symptoms are:

2.1. Profuse Sweating. 2.2. Nausea. 2.3. Dizziness2.4. Muscle cramps, generally in the legs & abdomen are the general symptoms.

Workplace Risk Assessment: A Key Step in Improving Safety

3. Employee should be training in basic first aid and the First Aid for heat exhaustion is:

3.1. Help the employee to lay down in the shade or air-conditioned area for the body temperature control.

3.2. Provide enough water - Give in small quantities every 2 to 3 minutes until the employee recovers.

3.3. Call for support from the Medical Facilities.

3.4. Remember - DO NOT gives salt or ice.

3.5. Instead apply cool water to the back of the neck and wrist.

4. Heat stroke is potentially life threatening and it occurs very rare, Heat stroke may occur after heat exhaustion has set in and has the below symptoms.

4.1. The body of the sufferer stops sweating but is very hot to the touch.

4.2. The employee will be disoriented or may become unconscious.

4.3. The employee generally will suffer condition of heat exhaustion prior to heat stroke effects.

Safety Training Videos with Pictorial Guidelines

5. The basic First Aid for heat stroke is:

5.1. Call for company/local medical assistance immediately.

5.2. Move the sufferer into shade or air-conditioned area for the body temperature control.

5.3. If available, Pack the ice, around the sufferers wrists, under the arms, and groin area. If ice is not available, use water.

5.4. If the sufferer is conscious give small amounts of water to drink every 2 to 3 minutes.

5.5. Remove clothing of the employee in the chest to torso.

5.6. Remember - Do not allow stroke sufferer to swallow ice and DO NOT give salt.

6. Keep the sufferer calm and wait for the medical assistance to arrive for the medical support to the employee.

Chain Pulley Block Safety







SPILL & WASTE CONTROL

 

SPILL & WASTE CONTROL

SPILL & WASTE CONTROL

Spill and waste control in any industry is very much important as it may lead to incidents and environmental concerns. The most common spills encountered by employees in industry are around moving oil and diesel, leachate, chemical spills and fire water run-off. The most crucial measures employed to prevent & contain spills include carrying out risk assessments (may be a requirement of the respective local government legislation), implementing Environment Management Plan(EMP) and employee training. Some control measures described included spill kits, double skinned tanks and sealed drainage systems i.e. a system that is not connected to surface or foul sewer such as a sealed sump. The Spills will cause damage and cost money. It is in every employees responsibility to prevent spills and where necessary contain them safely.

Ventilation Requirements for Confined Space

1.Always ensure that the hazardous waste material shall be stored in a separate dedicated storage area – Radioactive material require special measures(follow as per SDS).

2.The area shall have an impermeable surface with a suitable effective drainage control, roofing and be properly banded.

3.Ensure that the quantities stored in the area shall be kept to an absolute minimum.

4.The chemical containers shall be marked with warning labels to precisely describe their contents in a legible way.

5.Hazardous chemicals shall be stored and handled in accordance with the Manufacturer’s Safety Data Sheet (SDS) or as per the Customer or Local Government Regulatory Authority Requirements. All employees who are handling need to be trained.

The Importance of Electrical Safety in Industry

6.All the relevant Safety Data Sheet (SDS) to be displayed at the Chemical Storage Area and the location where chemicals are being used.

7.Ensure the usage of correct tools in transporting, loading, filling materials and fluids which can be controlled and contained with the use of suitable Hoppers, Nozzles, Funnels to avoid the spill, use required PPE – Personal Protective Equipment required

8.All polluted materials (such as rags, gloves..) to be disposed of in RED Tag area.

9.Food waste will be a source of high risk to the project site and employees; it will invite wild life to the site area (such as: scorpions, snakes, birds, rats, dogs, cats,..) also can cause many diseases.

10.Train all the employees as how to react & respond - In case of leak or spill employee should act quickly to: a)Isolate / stop leak from the source, b)Use absorbent material to mop up the spill, c)Dispose of polluted absorbent material and contaminated soil in heavy plastic sacks and placed in suitable (RED) containers. The same to be disposed/treated as per the Customer or Local Government Regulatory Authority Requirements.

 Hot Work Safety - A Complete Guide






RESPIRATORY PROTECTION – Definition of Terms

 

RESPIRATORY PROTECTION –

 Definition of Terms

RESPIRATORY PROTECTION – Definition of Terms

Air Purifying Respirator is a respirator with an air purifying filter, cartridge, or canister that removes specific air contaminants by passing ambient air through the air purifying element.

Atmosphere-supplying Respirator which supplies the user with breathing air from a source independent of the ambient atmosphere, including supplied-air respirators (SARs) and self-contained breathing apparatus (SCBA) units.

Demand Respirator - An atmosphere supplying respirator that admits breathing air to the face piece only when negative pressure is created inside the face piece by inhalation.

End-of-Service-Life-Indicator (ESLI) - A system that warns the respirator user of the approach of the end of adequate respiratory protection; for example, the sorbent is approaching saturation or is no longer adequate.

Managing Heat Stress in the Workplace : A Complete Guide

Escape-only Respirator which is intended to be used only for emergency exit.

Filtering Face Piece (dust mask) - A negative pressure particulate respirator with a filter as an integral part of the face piece or with the entire face piece composed of the filtering medium.

Fit Factor – Its an quantitative estimate of the fit of a particular respirator to a specific individual; typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn.

Fit Test - The use of protocol to qualitatively or quantitatively evaluate the fit of a respirator on an individual. (See Qualitative Fit Test (QLFT) and Quantitative Fit Test (ANFT).)

High Efficiency Particulate Air (HEPA) Filter - A filter that is at least 99.97% efficient in removing monodisperse particles of 0.3 micrometers in diameter. The equivalent NIOSH 42 CFR 84 particulate filters are the N100, R1000, and P100 filters.

The Importance of Electrical Safety in Industry

Immediately Dangerous to Life or Health (IDLH) - An atmosphere which poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual’s ability to escape from a dangerous atmosphere.

Loose-fitting Facepiece - A respiratory inlet covering that is designed to form a partial seal with the face.

Negative Pressure Respirator (tight fitting) - A respirator in which the air pressure inside the facepiece is negative during inhalation with respect to the ambient air pressure outside the respirator.

Oxygen Deficient Atmosphere - An atmosphere with an oxygen content below 19.5% by volume.

Positive Pressure Respirator - A respirator in which the pressure inside the respiratory inlet covering exceeds the ambient air pressure outside the respirator.

Powered Air-purifying Respirator (PAPR) - An air-purifying respirator that uses a blower to force the ambient air through the air-purifying elements to the inlet covering.

Chemicals Hazards, Storage & Protection

Pressure Demand Respirator - A positive pressure atmosphere-supplying respirator that admits breathing air to the facepiece when the positive pressure is reduced inside the facepiece by inhalation.

Qualitative Fit Test (QLFT) - A pass/fail test to assess the adequacy of respirator fit that relies on the individual’s response to the test agent.

Quantitative Fit Test (QNFT) - An assessment of the adequacy of respirator fit by numerically measuring the amount of leakage into the respirator.

Service Life - The period of time that a respirator, filter or sorbent, or other respiratory equipment provides adequate protection to the wearer.

Supplied –Air Respirator (SAR) or Airline Respirator - An atmosphere-supplying respirator for which the source of breathing air is not designed to be carried by the user.

Tight-fitting Facepiece - A respiratory inlet covering that forms a complete seal with the face.

User Seal Check - An action conducted by the respirator user to determine if the respirator is properly sealed to the face.









CONTROL OF HAZARDOUS ENERGY SOURCES

 

CONTROL OF HAZARDOUS 

ENERGY SOURCES

CONTROL OF HAZARDOUS ENERGY SOURCES


Its very important to protect the employees against the inadvertent or unintended release of energy, movement, or flow in electrical, mechanical, or material systems, which could result in injury to employees. Energy isolation with Lockout of these systems must be utilized.

Hazardous energy control procedures will be used to ensure that machines or equipment being inspected are isolated from all potentially hazardous energy and locked out before employees perform any work activities where unexpected energizing, start up, or release of stored energy could cause injury to the employee and his coworker. All kind of energies to be considered in this program like electrical, mechanical, process, chemical, hydraulic, pneumatic, steam etc.

The Importance of Electrical Safety in Industry

The below listed guidance for locking out(LOTO) machines and equipment. The equipment may, and often will, include more than one energy source and/or multiple isolating points for the safe maintenance. The energy sources will include electrical, mechanical, hydraulic, pneumatic, and other forms of energy, such as residual energy from spring tension or the effects of gravity. If at any time the authorized employee is uncertain that the employer’s lockout procedures sufficiently isolate and control all of the hazardous energy sources, the authorized employee will not proceed with lockout, and will use alternate safe procedures to document potential hazards. The written energy isolating procedure with the training to all authorized and affected employee is very important in hazardous energy control program for any industry.

 Ventilation Requirements for Confined Space

1. Only an authorized employee will lockout equipment. Every authorized employee exposed to the hazard must lockout the equipment – LOTO(Lock out & Tag out)

2. Only locks and tags issued by the employee/agency that are designated for lockout purposes are permitted for use by authorized employees. Authorized employees are not permitted to borrow locks for use.

3. The authorized employee will comply with OSHA requirements and with the employer’s lockout program as long as it meets or exceeds the OSHA requirements.

4. The authorized employee will assure that the employer’s authorized employee fully de-energizes the equipment/machine and utilizes an appropriate and effective energy isolating device(s) for the equipment/machine. The verification of isolation is very important to know the equipment is fully isolated. The authorized employee will then place his or her lock(s) on each isolating device for the equipment along with any other person(s) that may be exposed.

Ensure Safe Handling of Gas Cylinders 

with these Essential Tips

5. After ensuring that no personnel are exposed to hazards, the employer’s authorized employee will conduct a verification of the lockout by operating the push button or other operating controls to assure that the equipment will not operate. The isolation verification to recorded. The authorized employee will observe the employer’s authorized employee return the operating controls to the off or neutral position after the test. At no time will the employee attempt to activate/operate the employer’s equipment. Many industry the personal LOTO system is followed.

6. Once the equipment is locked-out, the authorized employee will limit their time of exposure to the absolute minimum needed to complete the inspection.

Chemicals Hazards, Storage & Protection

7. The lockout device will only be removed from the energy-isolating device by the authorized employee who applied it. When the employee removes a lockout device, the employee must notify their responsible Manager(s) prior to leaving the worksite.

8. If the lockout device is unintentionally left on the equipment, the employee’s responsible Manager(s) will contact the employee to verify their location and the employee will return to the site for lock removal. Where the employee cannot return to the site, the employee’s responsible Manager(s) may authorize removal of the lock only after the employee’s location is verified and the employee is informed of the lock removal.