Electrical Construction Activity
Safety Measures for GAS HAZARDS
- Cable Trays & Ladders will be
“as specified” type as per the approved material & standard submittal.
- All accessories used such as
“bends”, intersections, risers, reducers, elbows, etc. “used in cable trays
& ladders will be of the same manufacturer as that of the trays &
ladders.
- Prior to start any installation
of Trays & Ladders, a complete coordination will be carried out with other
mechanical services to avoid any interference or interrupted for the service.
The hazards to be communicated with all the working team members.
- Tray / ladders routes will be marking at the ceiling before start any fixing of these items.
- Each run of cable trays &
ladders will be completed before installation of any cables. Each run will be
aligned, leveled & securely fastened to the ceiling / wall. Ensure ladders
are properly secured at bottom & top.
- Supports will be provided to
prevent stern on cables entering or leaving tray. Cable trays extending through
partitions & walls will be protected by fireproof noncombustible barriers.
- Sharp edges, burns &
projection will be removed for fixing the trays & ladders approved
suspension rods or steel angle brackets will be used at spacing not exceeding
1.5 meter and generally as shown on the approved drawings. Joints will be
positioned as close as practicable to the tray / ladder supports. Ensure the usage
of cut resistant gloves and all other PPE as required for this activity.
- The fitting of trays & ladders such as tees, bends & crossings will be connected with radial to permit cable-bending standards.
- Minimum clearance of 250mm will
be maintained between top of tray & ceiling.
- Cable arrangement will be in one
layer only, evenly spaced, with minimum spacing of two diameters of he larger
of the two adjacent cables, or of a trefoil formation of single core cable
circuit.
- Cable trays will provide direct
support to the cables without cleats or saddles wherever practicable purpose
made straps, cleats or saddles will however be used to maintain a neat or
regular disposition of cables. In vertical tray installation or where trays not
directly support the cables, load bearing cable cleats or saddles will be
employed and securely fixed to the tray. Manufacturer’s recommendations will be
followed in selection of cable cleats or saddles, on the basis of individual application.
Ensure the fall protection PPE and its anchored properly.
- Earthing jumpers will be
installed on trays & ladders between the lengths and where required to
ensure effective electrical continuity irrespective of whether a separate protective
earth conductor is required or not. Ensure there is no material stored below
the activity area.
FIRE PUMP SYSTEM
Definitions of Terms in Chemical Safety
Fire pumps are used to enhancement the water pressure in sprinkler and standpipe systems and to deliver the required amount of water. This is essential when the system is fed by a non-pressurized water tank, or when the water supply feeding the system has inadequate pressure. A fire pump may be driven by an electric motor, diesel engine, or steam turbine.
National Fire Protection Association - NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, contains design and installation details for fire pump installations.
National Fire Protection Association -NFPA 20 requires electrical monitoring of pump controllers for pump running, power failure, or controller trouble. These remote alarm signals are often combined into fire alarm annunciators, so that fire departments may identify the status of a given fire pump.
A fire pump controller is the enclosure that contains controls and status indicators for a fire pump. National Fire Protection Association -NFPA 20 requires these devices to be within sight of the fire pump motor or engine. Fire service personnel may need access to this equipment during the course of a fire.
National Fire Protection Association-NFPA 20 contains dependability requirements for the power supply to an electrically driven fire pump. For example, power supply lines must be protected and the circuit must be independent of a building’s electric provision.
The latter feature allows the fire service to shut down building power while the fire pump continues to run. The most required location for a fire pump is in a separate building. This affords the most protection from fire, and gives fire-fighters easy access to the pump and its controllers. If locating the pump in a separate building is not possible, a fire-rated room with an outside entrance is the next best option.
Safety Warning Signs for Workplace Awareness
National Fire Protection Association-NFPA 20 requires pump rooms to be separated from the rest of the building by 2-hour fire rated construction in buildings without full sprinkler protection, and 1-hour construction in fully sprinklered buildings.
Ensure, Inside and outside entrances to fire pump rooms should be labelled with signage. Minimum lettering size should be six inches high with a 1/2 inch stroke (thickness of lines in each letter).
Procedure for Fire and Emergency Drill
Construction Safety Pictorial Guidelines
Drill is very important in every industry as how we are
prepared for a emergency situation. A drill involves of a conjectural scenario
which pose threat to life and industry is considered and procedures are
executed to ensure emergency response for safety of occupants and to control
and minimize the loss.
When directing drills, a set process should be followed in order to minimize risks of injury to personnel, damage to equipment or the environment. Members should be briefed how to inform fire and emergency organizations such as the fire, police, health and emergency response units depending upon the type of fire and emergency condition. In the drill and role play, occupiers should be given role of above-mentioned consultants as required by the emergency scenario. They should be notified before the beginning of the drill, and should respond accordingly as required by the drill scenario. They should also be informed as to how they will be notified in the event of an real emergency.
Ensuring Safety at Heights in Industry
Right communication is important, The drill controller should hold a pre-drill briefing with the participating agencies, observers/evaluators to explain the scene and the ground rules for executing the drill. Operational procedures should be reviewed and safety precautions should be considered and reviewed with the participants. The pre-drill briefing should include the outline of the drill procedure and should clearly specify the inputs required by the participating agencies in terms of human resource support/equipment support. In a scenario which has a potential to cause damage to the habitat, it is important to involve the community and discuss the possible chain of events with them. Clear communication established will all the stakeholders.
The drill should be initiated by the Fire Safety Incident Commander in accordance with the planned drill scenario. The exact actions such as alarm or announcement for the initiation should be identified and drill should be announced to begin. The initiation alarm should be locally identified and should be understood by all the participants. The alarm should reach in all area of the industry and all the persons in the industry should trained on the alarm.
All employees must be trained in the emergency evacuation. After the drill is initiated, every activity and response should be carried out according to the scenario and the Standard Operation Procedures - SOP stated out by the Fire Safety Officer. During the drill, Observers document all activities based on the criteria of the drill scenario. Each drill should have specified areas of evaluation so that all actions required are observed and evaluated. Necessary evaluation formats should be circulated in advance to the concerned participating observers and participants.
ISO 45001 Internal Audit
ISO standards widely followed in almost all countries in the
globe. ISO (International Organization for Standardization) is a international confederation
of national standards bodies. ISO is a nongovernmental organization that
comprises standards bodies from more than 160 countries, with one standards
body demonstrating each member country.
The videos will help you carryout the internal audit in your company as per the ISO45001 Requirements.
Definitions of Terms in Chemical Safety
ISO (International Organization for Standardization) develops standards to ensure the quality, safety and efficiency of products, services and systems. It has various standards for the same, ISO 45001 is one of them.
Steam Hazards and Safety Requirements
ISO 45001 specifies requirements for an occupational health and safety (OH&S) management system, and gives guidance. Introduced in March 2018, it's replaced the standard (BS OHSAS 18001).
Chemicals Hazards, Storage & Protection